DEFIBRILLATOR Input: ECG via QUIK-COMBO or FAST-PATCH disposable electrodes. Standard placement (anterior-lateral). Electrical Protection: Input protected against high voltage defibrillator pulses per IEC 60601/EN 60601. Safety Classification: Internally powered equipment IEC 60601-1/EN 60601-1, 5.1. Waveform: Monophasic pulse (Edmark) per AAMI DF2 1989, 3.2.1.5.1. Biphasic truncated exponential, with voltage and duration compensation for patient impedance.* Output Energy Sequence: Monophasic: 200, 200, 360 joules (360 joules thereafter) or 200, 300, 360 joules (360 joules thereafter). Biphasic: Three levels, user configurable from 200 to 360 joules, delivered (Level 1, Level 2, Level 3, Level 3...). Charge Time: With a new, nonrechargeable battery pak, or a new, fully charged rechargeable battery pak: 200 joules in less than 9 seconds 360 joules in less than 15 seconds
Controls:
ON/OFF
Turns device power on or off.
ANALYZE (optional)
Starts ECG analysis.
SHOCK
Delivers defibrillation energy. Active only when Shock Advisory System advises defibrillation.
Clock Set: Two switches are provided to set the clock. Display: Two-line, 20-character per line dot matrix Liquid Crystal Display. Low Battery Indicator: Low battery icon: At least 11 discharges remaining with nonrechargeable battery pak. At least 6 discharges remaining with rechargeable battery pak. Service Indicator: Service icon. Displayed Messages: Messages prompt user through complete operating sequence. Audible Tones: Coded tones assist user through device operation and alert operator of display messages. Voice Prompts: Prompt user through complete operation sequence. *Note: Specifications apply from 25 to 200 ohms. Voltage compensation is limited to the voltage that would result in delivery of 360 joules into 50 ohms.
EVENT DOCUMENTATION Type: Internal digital memory. Memory Capacity: 20 minutes audio recording (optional). ECG and event log of operator/device actions: At least 20 minutes if unit is configured with audio recording and audio recording setup option is ON. At least 80 minutes if configured with audio recording and audio recording setup option is OFF. At least 60 minutes if not configured with audio recording. Report Types: CODE SUMMARY report, Event Log report, Test Log report. Capacity: 300 Event Log events. 30 Test Log device tests (assuming no fault codes). Communications Options: • Direct connection to personal computer. • Modem connection to personal computer using Hayes AT-Compatible modem. • Print direct with EPSON ESC/P protocol for printers with 9-pin printheads. Data Review: LIFENET system compatible. Options: • DATA TRANSFER 500 information management program. • QUIK-VIEW 500 data review program. • CODE-STAT SUITE data management system, v2.0 or above.
ENVIRONMENTAL Operating Temperature: 0 to 50 C (+32 to +122 F). Storage Temperature: -30 to +65 C (-22 to +149 F) without battery and electrodes. -30 to +65 C (-22 to +149 F) with battery and electrodes, maximum exposure time limited to one week. Atmospheric Pressure: 760 to 429mmHg (0 to +15,000 ft above sea level). Relative Humidity: 0 to 95% (non-condensing). Water Resistance: IEC 60529/EN 60529 IPX4 “Splash-proof” with electrodes or connector cover installed. Shock: MIL-STD-810E, Method 516.4, Procedure 1 (40g, 6–9ms pulse, 1/2 sine each axis). Vibration: Monophasic version: MIL STD 810E, Method 514.4, Category 10. Biphasic version: MIL-STD-810E, Method 514.4, Helicopter—Category 6 (3.75 Grms) and Ground Mobile—Category 8 (3.15 Grms). RTCA D0 160C, Table 8–2 Fixed Wing—Turbojet Engine Classification C’ (Fuselage). Test level per Figure 8–5 C’. One hour in each of three axes. Aircraft: Tested to RTCA/DO-160C, “Environmental Conditions and Test Procedures for Airborne Equipment.” (Details available upon request.)
BATTERIES Note: See Operating Instructions for information on caring for batteries. Rechargeable SLA Battery Pak Type: Sealed lead-acid, 8V, 2.5 amp hours. Capacity: Typical: 59 full discharges or 3 hours of “ON” time with a new, fully charged battery. Minimum: 43 full discharges with a new, fully charged battery. Battery Charge Time: 10 hours. Battery charging limited to +15 to +35 C (+59 to +95 F). Recommended Replacement Interval: 2 years or 200 battery charge/discharge cycles, whichever comes first using recommended battery maintenance procedures. Weight: 0.9kg (1.9 lb). Nonrechargeable Lithium Sulphur Dioxide (LiSO2) Battery Pak Type: Sealed lithium, 12V, 7.5 amp-hours. Certification: FAA: TSO-C97 or CAA: BS2G237. Capacity: Typical: 312 full discharges or 14 hours of “ON” time. Minimum: 230 full discharges with a new battery. Shelf-Life: 5 years** (4 years for aircraft use.) Weight: 0.5kg (1.2 lb). Nonrechargeable Manganese Dioxide (LiMnO2) Battery Pak Type: Sealed lithium, 12V, 10.0 amp-hours. Capacity: Typical: 416 full discharges or 18 hours of “ON” time. Minimum: 230 full discharges with a new battery. Shelf-Life: 5 years. Weight: 0.5kg (1.2 lb).
**Note: See Operating Instructions for information on caring for batteries.
GENERAL Physical Characteristics Height: 10.2cm (4.0 in). Width: 26.7cm (10.5 in). Depth: 29.5cm (11.6 in) including handle. Weight: Monophasic version: 6.2 lbs (without battery or electrodes). Biphasic version: 5.3 lbs (without battery or electrodes).
Defibrillation protected, type BF patient connection.
All specifications are at 20C unless otherwise specified. All performance specifications assume the device has been stored (two hours minimum) at the operating temperature prior to operation.